Engineering Whitepapers

Why Medical Diagnostic Nozzles Failed to Fill

A Natech-reported medical nozzle case shows how Moldflow identified trapped gas and a three-piece insert redesign restored reliable filling.

Precision mold inserts and elongated lifter components arranged for injection mold tooling.
A short shot in a small medical nozzle can be more than a cosmetic defect. In a diagnostic component with separate fluid paths, incomplete geometry may undermine the function the part was designed to protect.
A case published by Natech in its injection-mold venting article describes multiple nozzles in a diagnostic test product failing to fill during preliminary production. The investigation traced the problem to trapped gas inside the steel insert. A tooling redesign then created additional venting paths. For medical-device engineers and mold buyers, the lesson is clear: when a local feature repeatedly fails to form, the restriction may be inside the tool structure rather than simply in the molding settings.

What made the nozzle short shot a functional problem?

Natech reports that the product used multiple nozzles. Each had a main channel and a parallel side channel. The side channel extended slightly beyond the main-channel tip to help prevent the two streams from cross-contaminating.
During preliminary production, the nozzle tips and required snorkel geometry did not fill completely. This could allow the input stream to cross-contaminate with the waste stream, compromising the integrity of the diagnostic result.
A short shot in a small internal feature should therefore be assessed against the component's function, not only its appearance. Buyers should identify which channel, tip, sealing surface or separation feature is incomplete and explain what that feature must do in the finished assembly.

How did the team locate the trapped air?

The nozzles were formed within a single steel insert. The team suspected that the insert arrangement restricted gas escape, but a suspected air trap alone was not enough to justify a tooling redesign.
Natech reports that its engineers used Moldflow simulation to examine filling behavior. The analysis confirmed that melt fronts converged inside the insert. Gas became trapped at that location and prevented the nozzle geometry from filling.
A flow-front meeting point is not automatically a defect. The key question is whether the converging fronts leave a gas pocket without an effective escape route. Simulation can help locate likely air traps, but the result must be interpreted against the actual cavity, insert boundaries and available vent paths.
For another project, compare the predicted air-trap location with the physical tool layout. Examine the end-of-fill region, local shut-offs, insert interfaces and possible routes to the parting line or other venting features.

Why were process adjustments not enough?

Natech initially considered whether process changes could resolve the non-fill without modifying the mold. Its article identifies temperature, clamp force, ejection velocity and cycle time as variables considered for investigation.
That is a sensible diagnostic sequence: process conditions should be reviewed before committing to a tooling change. However, changing settings cannot reliably solve every trapped-gas problem. If the insert geometry encloses the air pocket, a wider process window may not create a physical escape route.
The distinction is between a process-limited fill problem and a structural venting limitation. Both may contribute, so neither should be assumed without evidence. Review the material and processing window, filling behavior and machine conditions alongside the mold's actual venting geometry.

Why did the three-piece insert redesign work?

After Moldflow confirmed the trapped-gas location, Natech reports that the team redesigned the original insert as a three-piece structure. The interfaces between the plates created additional parting-line opportunities for gas to escape. One parting line was positioned at the plane of the nozzle tips.
Natech reports that the new parting lines allowed the trapped gas to escape and the nozzles to fill properly and reliably.
The lesson is not that every nozzle insert should be divided into three pieces. It is that insert architecture can create a venting route where gas is trapped. Depending on the part and mold layout, alternatives may include a revised parting line, a local vent insert, suitable ejector-related venting or a porous/sintered insert. Each option must be assessed against the actual geometry and manufacturing constraints.

What should buyers check before approving a similar tool?

A split insert can solve one problem while introducing others. Before approving a redesign, the project team and mold supplier should review:
  • Insert alignment: Will the separate plates locate repeatably and maintain the required relationship to the nozzle features?
  • Shut-off and flash risk: Can the interfaces seal where plastic must not enter while providing a controlled gas path where required?
  • Machining and assembly: Can the mating faces and critical features be manufactured, inspected and assembled consistently?
  • Wear and maintenance: Could the interfaces become damaged, contaminated or difficult to clean during production and maintenance?
  • Part quality: Could a vent mark, mismatch or flash affect the nozzle tip, fluid path or functional interface?
  • Validation: Which filling, dimensional and functional checks will demonstrate that the revised tool meets agreed requirements?
JST precision wire-EDM centering sliders, shown as a separate example of precision tooling components.
Venting must be specific to the resin, geometry, process window and acceptance criteria. Do not approve a vent depth, clearance or split-line arrangement from a generic rule without checking the project.
For a DFM review, provide the 3D part model, 2D drawing, resin grade, critical dimensions, functional description of each fluid path, expected production volume, available molding conditions and photographs or samples showing the short-shot location. For an existing tool, include insert drawings and trial observations where available.

How does this relate to JST's insert and Moldflow engineering work?

The Natech case is not a JST project, and its three-piece medical nozzle insert should not be confused with a JST product. The connection is the broader tooling challenge: complex insert geometry must be machined accurately and designed with a practical route for gas release.
JST's Precision Mold Inserts | Modular High-Performance Components is the related product reference for this article. The page presents high-precision cavity inserts and lifter systems, with precision machining and Mirror EDM for complex tooling components. This is a relevant JST product relationship, not evidence that JST supplied the insert used in the Natech case or that the pictured components use the same venting architecture.
For simulation context, JST explains how Moldflow can help review filling behavior and predicted air traps before tooling decisions are finalized in How Moldflow Analysis Reduces Injection Mold Risk Before Steel Cutting. Simulation supports engineering decisions; it does not replace actual mold trials and part validation.
The practical buying question is whether a supplier can connect the predicted air-trap location to a manufacturable insert and venting concept, explain the trade-offs, and agree on how the molded part will be validated.

FAQ

Does every nozzle short shot mean the mold has an air-trap problem?

No. Incomplete filling can have several causes, including material, process, gate, flow-path or venting limitations. In the Natech case, Moldflow supported the trapped-gas diagnosis. Another project needs its own evidence before the cause is assigned.

Is a three-piece insert the recommended solution for all small nozzles?

No. It was the reported solution in this case. A parting-line change, local vent insert, ejector-related venting or another design may be more suitable depending on geometry, sealing requirements, machining access and maintenance.

What should be included in a DFM review for a venting-sensitive medical component?

Provide the 3D model, available 2D drawings, resin grade, critical dimensions, functional requirements for the channels and tips, expected volume, current tooling concept and any trial evidence. Identify which incomplete feature affects product function.

Can Moldflow guarantee that the redesigned insert will pass production validation?

No. Simulation helps locate likely filling and air-trap risks and compare design options. The final tool still requires trial-based evaluation, dimensional inspection and functional checks against agreed acceptance criteria.

How can a buyer assess whether a mold supplier can manufacture a complex vented insert?

Ask the supplier to explain the insert split, locating and sealing strategy, machining/EDM approach, vent maintenance access and validation plan. Request evidence relevant to the actual geometry and drawing requirements rather than relying on a generic capability statement.

Request an Engineering Review for Your Mold Insert

If your diagnostic or fluid-handling component has incomplete nozzle tips, trapped-air concerns or complex insert geometry, send JST your 3D CAD model, 2D drawing, resin grade, critical dimensions, functional requirements and any available trial observations. JST can review the tooling questions against the supplied project information and discuss an appropriate DFM or quotation scope.